Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
Article in English | MEDLINE | ID: mdl-38649588

ABSTRACT

BACKGROUND: Ventricular tachycardia (VT) reduces cardiac output through high heart rates, loss of atrioventricular synchrony, and loss of ventricular synchrony. We studied the contribution of each mechanism and explored the potential therapeutic utility of His bundle pacing to improve cardiac output during VT. METHODS: Study 1 aimed to improve the understanding of mechanisms of harm during VT (using pacing simulated VT). In 23 patients with left ventricular impairment, we recorded continuous ECG and beat-by-beat blood pressure measurements. We assessed the hemodynamic impact of heart rate and restoration of atrial and biventricular synchrony. Study 2 investigated novel pacing interventions during clinical VT by evaluating the hemodynamic effects of His bundle pacing at 5 bpm above the VT rate in 10 patients. RESULTS: In Study 1, at progressively higher rates of simulated VT, systolic blood pressure declined: at rates of 125, 160, and 190 bpm, -22.2%, -42.0%, and -58.7%, respectively (ANOVA p < 0.0001). Restoring atrial synchrony alone had only a modest beneficial effect on systolic blood pressure (+ 3.6% at 160 bpm, p = 0.2117), restoring biventricular synchrony alone had a greater effect (+ 9.1% at 160 bpm, p = 0.242), and simultaneously restoring both significantly increased systolic blood pressure (+ 31.6% at 160 bpm, p = 0.0003). In Study 2, the mean rate of clinical VT was 143 ± 21 bpm. His bundle pacing increased systolic blood pressure by + 14.2% (p = 0.0023). In 6 of 10 patients, VT terminated with His bundle pacing. CONCLUSIONS: Restoring atrial and biventricular synchrony improved hemodynamic function in simulated and clinical VT. Conduction system pacing could improve VT tolerability and treatment.

3.
Article in English | MEDLINE | ID: mdl-38124803

ABSTRACT

Background: The prognostic impact of ventricular tachycardia (VT) catheter ablation is an important outstanding research question. We undertook a reconstructed individual patient data meta-analysis of randomised controlled trials comparing ablation to medical therapy in patients developing VT after MI. Methods: We systematically identified all trials comparing catheter ablation to medical therapy in patients with VT and prior MI. The prespecified primary endpoint was reconstructed individual patient assessment of all-cause mortality. Prespecified secondary endpoints included trial-level assessment of all-cause mortality, VT recurrence or defibrillator shocks and all-cause hospitalisations. Prespecified subgroup analysis was performed for ablation approaches involving only substrate modification without VT activation mapping. Sensitivity analyses were performed depending on the proportion of patients with prior MI included. Results: Eight trials, recruiting a total of 874 patients, were included. Of these 874 patients, 430 were randomised to catheter ablation and 444 were randomised to medical therapy. Catheter ablation reduced all-cause mortality compared with medical therapy when synthesising individual patient data (HR 0.63; 95% CI [0.41-0.96]; p=0.03), but not in trial-level analysis (RR 0.91; 95% CI [0.67-1.23]; p=0.53; I2=0%). Catheter ablation significantly reduced VT recurrence, defibrillator shocks and hospitalisations compared with medical therapy. Sensitivity analyses were consistent with the primary analyses. Conclusion: In patients with postinfarct VT, catheter ablation reduces mortality.

4.
Article in English | MEDLINE | ID: mdl-37457437

ABSTRACT

Guidelines help clinicians to deliver high-quality care with therapies based on up-to-date evidence. There has been significant progress in the management of heart failure with regards to both medication and cardiac device therapy. These advances have been incorporated into national and international guidelines with varying degrees of success. This article reviews current guidance from the National Institute of Health and Care Excellence in the UK and compares this with European Society of Cardiology guidelines, and evaluates how differences between them may impact on clinical practice.

5.
Europace ; 25(3): 1077-1086, 2023 03 30.
Article in English | MEDLINE | ID: mdl-36352513

ABSTRACT

Guidelines recommend patients undergoing a first pacemaker implant who have even mild left ventricular (LV) impairment should receive biventricular or conduction system pacing (CSP). There is no corresponding recommendation for patients who already have a pacemaker. We conducted a meta-analysis of randomized controlled trials (RCTs) and observational studies assessing device upgrades. The primary outcome was the echocardiographic change in LV ejection fraction (LVEF). Six RCTs (randomizing 161 patients) and 47 observational studies (2644 patients) assessing the efficacy of upgrade to biventricular pacing were eligible for analysis. Eight observational studies recruiting 217 patients of CSP upgrade were also eligible. Fourteen additional studies contributed data on complications (25 412 patients). Randomized controlled trials of biventricular pacing upgrade showed LVEF improvement of +8.4% from 35.5% and observational studies: +8.4% from 25.7%. Observational studies of left bundle branch area pacing upgrade showed +11.1% improvement from 39.0% and observational studies of His bundle pacing upgrade showed +12.7% improvement from 36.0%. New York Heart Association class decreased by -0.4, -0.8, -1.0, and -1.2, respectively. Randomized controlled trials of biventricular upgrade found improvement in Minnesota Heart Failure Score (-6.9 points) and peak oxygen uptake (+1.1 mL/kg/min). This was also seen in observational studies of biventricular upgrades (-19.67 points and +2.63 mL/kg/min, respectively). In studies of the biventricular upgrade, complication rates averaged 2% for pneumothorax, 1.4% for tamponade, and 3.7% for infection over 24 months of mean follow-up. Lead-related complications occurred in 3.3% of biventricular upgrades and 1.8% of CSP upgrades. Randomized controlled trials show significant physiological and symptomatic benefits of upgrading pacemakers to biventricular pacing. Observational studies show similar effects between biventricular pacing upgrade and CSP upgrade.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Pacemaker, Artificial , Ventricular Dysfunction, Left , Humans , Cardiac Resynchronization Therapy/adverse effects , Cardiac Pacing, Artificial/adverse effects , Cardiac Conduction System Disease/therapy , Heart Conduction System , Ventricular Function, Left , Stroke Volume/physiology , Treatment Outcome , Heart Failure/diagnosis , Heart Failure/therapy
6.
Europace ; 25(2): 341-350, 2023 02 16.
Article in English | MEDLINE | ID: mdl-36305545

ABSTRACT

AIMS: The effect of atrial fibrillation catheter ablation on cardiovascular outcomes in heart failure is an important outstanding research question. We undertook a meta-analysis of randomized controlled trials comparing ablation to medical therapy in patients with AF and heart failure. METHODS AND RESULTS: We systematically identified all trials comparing catheter ablation to medical therapy in patients with heart failure and atrial fibrillation. The pre-specified primary endpoint was all-cause mortality in trials with at least 2 years of follow-up. The secondary endpoint was heart failure hospitalization. Sensitivity analyses were performed for trials with any follow-up and trials deemed at low risk of bias. Eight trials (1390 patients) were included. Seven hundred and seven patients were randomized to catheter ablation and 683 to medical therapy. In the primary analysis (three trials, n = 977), catheter ablation reduced mortality compared with medical therapy [relative risk (RR): 0.61, 95% confidence interval (CI): 0.44 to 0.84, P = 0.003]. Catheter ablation also reduced heart failure hospitalizations compared with medical therapy (RR: 0.60, 95% CI: 0.49-0.74, P < 0.001). The effect on stroke was not statistically significant (RR: 0.62, 95% CI: 0.28-1.37, P = 0.237). There was low heterogeneity between studies. Sensitivity analyses were consistent with the primary analyses. CONCLUSION: In patients with atrial fibrillation and heart failure, catheter ablation reduces mortality and the occurrence of heart failure hospitalizations.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Heart Failure , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/complications , Anti-Arrhythmia Agents/therapeutic use , Randomized Controlled Trials as Topic , Heart Failure/diagnosis , Heart Failure/therapy , Catheter Ablation/methods , Treatment Outcome
9.
Br J Pain ; 11(1): 32-35, 2017 Feb.
Article in English | MEDLINE | ID: mdl-28386402

ABSTRACT

A 76-year-old man was admitted to hospital with a right-sided fractured neck of femur requiring repair via a cemented hemiarthroplasty. Intraoperatively he received 10 mg of intravenous morphine. Post-operatively he received a short course of low-dose oral opioids and subsequently developed myoclonic jerks and hyperalgesia. The opioids were discontinued and both adverse effects resolved. This case report discusses the concurrent development of myoclonus and hyperalgesia following a low dose of opioids and explores possible management options.

10.
Ann Thorac Surg ; 103(4): e313-e315, 2017 Apr.
Article in English | MEDLINE | ID: mdl-28359485

ABSTRACT

Giant coronary artery aneurysm (CAA) is a rare clinicopathologic entity, and there is a dearth of information regarding presentation, diagnosis, and subsequent management. We present a case of a giant aneurysm of the proximal right coronary artery (RCA) that was 1.5 × 1.5 cm with direct communication between the aneurysmal cavity and the aortic sinus. The deficit in the RCA ostium was closed with a patch of bovine pericardium. The distal communication of the aneurysm to the mid-RCA was clearly delineated and tied off. The distal RCA was grafted under bypass with a long saphenous vein. Although our case is not unique, it does represent an uncommon presentation of a rare disease process.


Subject(s)
Coronary Aneurysm/diagnostic imaging , Coronary Aneurysm/surgery , Aged , Female , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...